DocumentCode :
1819419
Title :
Estimating remaining BDV and life expectancy for stator winding insulation of rotating machines by using nondestructive insulation diagnostic data
Author :
Nakayama, Akinobu ; Haga, Kohji ; Muraoka, Masayoshi ; Fukuchi, Kikuo
Author_Institution :
Generator Dept., Fuji Electr. Co. Ltd., Kawasaki, Japan
Volume :
1
fYear :
2003
fDate :
1-5 June 2003
Firstpage :
286
Abstract :
We have investigated an appropriate life expectancy estimating method of the epoxy resin-rich insulation system (Fuji F-class Stabilastic insulation system). We have already collected the BVD and the nondestructive insulation diagnostic data from 30 or more units of the rotating electric machines provided epoxy resin-rich insulation system with the rated voltage of 3.3 to 11 kV. We have performed a multivariate analysis on the BVD and the nondestructive insulation diagnostic data of these coils in this time, and have established the estimating method for the remaining BVD and the life expectancy. On the basis of compared results of the measured values with the estimated values, it was proven that this estimating method provides enough accuracy for the actual use.
Keywords :
coils; electric breakdown; epoxy insulation; insulation testing; machine insulation; nondestructive testing; stators; 3.3 to 11 kV; Fuji F-class Stabilastic insulation system; breakdown voltage; coils; epoxy resin-rich insulation system; nondestructive insulation diagnostics; rotating electric machines; stator winding insulation; Coils; Dielectrics and electrical insulation; Electric machines; Insulation testing; Life estimation; Nondestructive testing; Power generation; Rotating machines; Stator windings; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
ISSN :
1081-7735
Print_ISBN :
0-7803-7725-7
Type :
conf
DOI :
10.1109/ICPADM.2003.1218408
Filename :
1218408
Link To Document :
بازگشت