• DocumentCode
    1820712
  • Title

    Tomosynthesis reconstruction from multi-beam X-ray sources

  • Author

    Lalush, David S. ; Quan, Enzhuo ; Rajaram, Ramya ; Zhang, Jian ; Lu, Jianping ; Zhou, Otto

  • Author_Institution
    Dept. of Biomedical Eng., North Carolina State Univ., Raleigh, NC
  • fYear
    2006
  • fDate
    6-9 April 2006
  • Firstpage
    1180
  • Lastpage
    1183
  • Abstract
    We investigate methods for reconstructing tomosynthesis data using arrays of microfabricated X-ray sources and area CCD detectors. Tomosynthesis is a 3D imaging technique for limited-angle tomography that uses multiple radiographic images taken from an X-ray source placed at several positions to estimate a 3D distribution of X-ray attenuation. In our implementation, the moving X-ray source is replaced with multiple carbon nanotube field-emission X-ray sources fabricated on a single wafer. The sources are individually addressable, so the motion of the single X-ray source in traditional tomosynthesis is replaced by sequential sampling of the individual sources. Reconstruction is performed using the ordered-subsets convex (OSC) algorithm with pre-computed geometry factors and an image shearing technique for efficiency. Because of the limited resolution of tomosynthesis along the primary direction of projection, reconstructions are computed on non-cubic voxels for relatively thick slabs. We demonstrate the capabilities of the reconstruction technique on simulated data and breast phantom data from a prototype device. Reconstructions for an 11-beam system with 1000times1000 pixels per projection onto a 800times800times20 grid require 55 minutes ( 10 iterations) on a 3.2 GHz workstation with 2 GB memory. We conclude that this implementation of the OSC algorithm is effective for reconstructing tomosynthesis datasets
  • Keywords
    biological organs; diagnostic radiography; image reconstruction; image resolution; iterative methods; mammography; medical image processing; phantoms; 3D imaging technique; 55 min; X-ray attenuation; area CCD detectors; breast phantom; image shearing; iterations; limited-angle tomography; multibeam X-ray sources; multiple carbon nanotube field-emission X-ray sources; ordered-subsets convex algorithm; precomputed geometry factors; radiographic images; tomosynthesis reconstruction; tomosynthesis resolution; Attenuation; Charge coupled devices; Image reconstruction; Optical imaging; Radiography; Sensor arrays; Tomography; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging: Nano to Macro, 2006. 3rd IEEE International Symposium on
  • Conference_Location
    Arlington, VA
  • Print_ISBN
    0-7803-9576-X
  • Type

    conf

  • DOI
    10.1109/ISBI.2006.1625134
  • Filename
    1625134