DocumentCode
182284
Title
Direct work function measurement of activated M-type dispenser cathodes
Author
Swartzentruber, Phillip ; Balk, T. John ; Tarter, James O. ; Busbaher, Daniel
Author_Institution
Dept. of Chem. & Mater. Eng., Univ. of Kentucky, Lexington, KY, USA
fYear
2014
fDate
22-24 April 2014
Firstpage
135
Lastpage
136
Abstract
M-type dispenser cathodes were activated in a vacuum chamber and the absolute work function determined from the contact potential difference between the cathode and a precisely calibrated probe tip. The experimental test setup allowed for cathodes to be activated and the work function measured without breaking vacuum. In addition to the commercially available Os-Ru coating from Ceradyne, Inc., a 3M Company, the work functions of Os-Ru coatings with engineered microstructures were measured to quantify microstructural influences. The work functions of both pre- and post-activation cathodes are presented and discussed in light of the microstructure of their Os-Ru coatings.
Keywords
thermionic cathodes; work function; Os-Ru coating; absolute work function; activated M-type dispenser cathodes; contact potential difference; direct work function measurement; post-activation cathodes; pre-activation cathodes; vacuum chamber; Cathodes; Coatings; Pollution measurement; Surface cleaning; Surface contamination; Temperature measurement; M-type; Os-Ru; microstructure; work function;
fLanguage
English
Publisher
ieee
Conference_Titel
Vacuum Electronics Conference, IEEE International
Conference_Location
Monterey, CA
Type
conf
DOI
10.1109/IVEC.2014.6857526
Filename
6857526
Link To Document