• DocumentCode
    182284
  • Title

    Direct work function measurement of activated M-type dispenser cathodes

  • Author

    Swartzentruber, Phillip ; Balk, T. John ; Tarter, James O. ; Busbaher, Daniel

  • Author_Institution
    Dept. of Chem. & Mater. Eng., Univ. of Kentucky, Lexington, KY, USA
  • fYear
    2014
  • fDate
    22-24 April 2014
  • Firstpage
    135
  • Lastpage
    136
  • Abstract
    M-type dispenser cathodes were activated in a vacuum chamber and the absolute work function determined from the contact potential difference between the cathode and a precisely calibrated probe tip. The experimental test setup allowed for cathodes to be activated and the work function measured without breaking vacuum. In addition to the commercially available Os-Ru coating from Ceradyne, Inc., a 3M Company, the work functions of Os-Ru coatings with engineered microstructures were measured to quantify microstructural influences. The work functions of both pre- and post-activation cathodes are presented and discussed in light of the microstructure of their Os-Ru coatings.
  • Keywords
    thermionic cathodes; work function; Os-Ru coating; absolute work function; activated M-type dispenser cathodes; contact potential difference; direct work function measurement; post-activation cathodes; pre-activation cathodes; vacuum chamber; Cathodes; Coatings; Pollution measurement; Surface cleaning; Surface contamination; Temperature measurement; M-type; Os-Ru; microstructure; work function;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Vacuum Electronics Conference, IEEE International
  • Conference_Location
    Monterey, CA
  • Type

    conf

  • DOI
    10.1109/IVEC.2014.6857526
  • Filename
    6857526