• DocumentCode
    1823213
  • Title

    Assembly of MCM thermal solution utilizing individual heat spreaders

  • Author

    Edwards, David L. ; Hering, Ronald L. ; Long, David C. ; Singh, Surinder

  • Author_Institution
    IBM Server & Technol. Group, Hopewell Junction, NY
  • fYear
    2006
  • fDate
    14-16 March 2006
  • Firstpage
    157
  • Lastpage
    161
  • Abstract
    Some recent IBM UNIX servers use multi-chip modules (MCMs) with multi-core processor chips with very high power densities, requiring aggressive thermal solutions. The thermal solution includes flip chips with individually attached heat spreaders. Because of the difficulty of reworking the thermal solution, and the high value of the module at the time the cooling solution is assembled, very high assembly yields were required. This drove new technologies, and new processes to enable assembly of highly efficient cooling structures with very high yields. This paper addresses the challenges of assembling the heat spreader cooling solution, and describes how these challenges were overcome
  • Keywords
    cooling; flip-chip devices; microassembling; microprocessor chips; multichip modules; network servers; thermal management (packaging); IBM UNIX servers; MCM thermal solution; assembly yields; cooling solution; flip-chip devices; heat spreaders; multichip module; multicore processor chips; Assembly; Circuits; Cooling; Copper; Multichip modules; Multicore processing; Silicon carbide; Thermal conductivity; Thermal expansion; Thermal resistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Semiconductor Thermal Measurement and Management Symposium, 2006 IEEE Twenty-Second Annual IEEE
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    1-4244-0153-4
  • Type

    conf

  • DOI
    10.1109/STHERM.2006.1625222
  • Filename
    1625222