DocumentCode
1823939
Title
Status of the CDF Run II silicon detector
Author
Clark, David K.
Author_Institution
Brandeis Univ., Waltham, MA, USA
Volume
3
fYear
2003
fDate
19-25 Oct. 2003
Firstpage
1638
Abstract
The 8 layer, 722 K channel CDF Run II silicon detector is an essential part of the heavy flavor tagging and forward tracking capabilities of the CDF experiment. A summary of the experience in commissioning and operating this double-sided silicon detector during the first two years of Run II is given. Results from offline reconstruction showing the detector resolution and efficiency as well as the impact of the silicon detector on the physics program of the experiment are presented.
Keywords
position sensitive particle detectors; silicon radiation detectors; 722 K; CDF Run II silicon detector; CDF experiment; detector resolution; double-sided silicon detector; forward tracking capabilities; heavy flavor tagging; offline reconstruction;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8257-9
Type
conf
DOI
10.1109/NSSMIC.2003.1352192
Filename
1352192
Link To Document