DocumentCode :
1824098
Title :
An automated active source and load pull measurement system
Author :
Williams, David J. ; Tasker, Paul J.
Author_Institution :
Cardiff Sch. of Eng., Cardiff Univ., UK
fYear :
2001
fDate :
2001
Firstpage :
7
Lastpage :
12
Abstract :
A fully automated electronic load and source pull measurement system has been developed using standard Agilent ESG Frequency sources. Combined with a vector corrected time-domain waveform measurement system based on the HP-MTA (Microwave Transition Analyser) enabling real time waveform measurements of the current and voltages to be obtained. The system has been validated using measurements performed on a Heterojunction Bipolar Transistor operating in Class B with constant harmonic terminations on the load and source over variations in drive level
Keywords :
automatic test equipment; heterojunction bipolar transistors; microwave bipolar transistors; microwave measurement; semiconductor device measurement; Agilent ESG frequency source; automated active source and load pull measurement system; class B operation; harmonic termination; heterojunction bipolar transistor; microwave transistor analyser; real-time waveform measurement; vector corrected time-domain waveform measurement; Current measurement; Frequency measurement; Heterojunction bipolar transistors; Measurement standards; Microwave measurements; Performance evaluation; Real time systems; Standards development; Time domain analysis; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High Frequency Postgraduate Student Colloquium, 2001. 6th IEEE
Conference_Location :
Cardiff
Print_ISBN :
0-7803-7118-6
Type :
conf
DOI :
10.1109/HFPSC.2001.962150
Filename :
962150
Link To Document :
بازگشت