Author :
Kokubun, M. ; Abe, K. ; Ezoe, Y. ; Fukazawa, Y. ; Hong, S. ; Inoue, H. ; Ito, K. ; Itoh, T. ; Kamae, T. ; Kasama, D. ; Kawaharada, M. ; Kawano, N. ; Kawashima, K. ; Kawasoe, S. ; Kobayashi, Y. ; Kotoku, J. ; Kouda, M. ; Kubota, A. ; Makishima, K. ; Mitani
Abstract :
We summarize significant improvements which have been achieved in the development of Astro-E2 Hard X-ray Detector (HXD-II). An expanded energy range and better energy resolution have been achieved from progresses in device materials and redesigning of the front-end electronics. An improved estimation for the detector background in orbit has also been conducted based upon results from our proton irradiation experiment. The sensitivity of HXD-II can be expected to reach an order of 10-6 [cs-1 keV-1 cm-2].
Keywords :
X-ray apparatus; X-ray detection; energy measurement; Astro-E2 Hard X-ray Detector; HXD-II sensitivity; detector background; device materials; energy resolution; front-end electronics; proton irradiation experiment; Chemicals; Circuits; Conducting materials; Crystals; Energy resolution; Instruction sets; Linear accelerators; Physics; Radiation detectors; X-ray detectors;