The electric tests of ordinate insulation in converter transformer by the method of applying voltage on single-phase
Author
Wang, Xuan ; Yang, Juanjuan ; Cao, Xiaolong ; Xu, Man ; Lv, Jingshun
Author_Institution
State Key Lab. of Electr. Insulation for Power Equip., Xi´´an Jiaotong Univ., China
Volume
3
fYear
2003
fDate
1-5 June 2003
Firstpage
1170
Abstract
Converter transformer is the key equipment in HVDC. In the great capability direct current system used in the nonferrous metal (e.g. aluminum) electrolytic production, converter transformers are parallel connected. In order to reduce harmonics into power system, these converter transforms are installed phase-shifting windings to produce different phases on high voltage AC side and the neutral point is grading insulated. According to 12 impulse technology, delta and wye connection windings are used at low voltage side. The three phases of those transformers including regulating transformer and control transformer are installed in a tank. Generally, withstand voltage and leave line partial discharge of the ordinate insulation are measured in laboratory. The voltage is inductively applied by three-phase double-frequency power. In this paper, based on the field test of a 110 kV, 7. 5 MVA converter transformer applying voltage on single-phase and other phases supported, a new method is provided to measure the withstand voltage of ordinate insulation in the converter transformer by using present single-phase test equipment.
Keywords
HVDC power convertors; aluminium; insulation testing; partial discharges; power conversion harmonics; power transformer insulation; power transformer testing; transformer windings; 110 kV; Al; HVDC; applying voltage; control transformer; converter transformer; converter transformers; delta connection; direct current system; electric tests; electrolytic production; harmonics; high voltage AC side; impulse technology; installed phase-shifting windings; leave line partial discharge; nonferrous metal; ordinate insulation; regulating transformer; single-phase test equipment; single-phase voltage; three-phase double-frequency power; withstand voltage; wye connection; Aluminum; Dielectrics and electrical insulation; HVDC transmission; Insulation testing; Low voltage; Partial discharge measurement; Partial discharges; Power system harmonics; Power transformer insulation; Production systems;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
ISSN
1081-7735
Print_ISBN
0-7803-7725-7
Type
conf
DOI
10.1109/ICPADM.2003.1218632
Filename
1218632
Link To Document