DocumentCode :
182525
Title :
Techniques of control flow measurement system and calibration of sensors
Author :
Harrouz, A. ; Benatiallah, A. ; Harrouz, O.
Author_Institution :
Dept. of hydrocarbon & renewable energy, Univ. of Adrar, Adrar, Algeria
fYear :
2014
fDate :
21-24 Sept. 2014
Firstpage :
48
Lastpage :
52
Abstract :
In this paper, we present procedure of control of metering system. The metrological control for a flow measurement is discussed and analyzed. We present calibration of sensory instruments installed and experimental results from a skid of metering on oil industry. It combines the notion of calibration function and a controller procedure recursively. First, the control is utilized to obtain the error of instruments. The simulation results clearly show that the errors respect of the tolerance defined by the international standards and recommendations. Secondly, some experimental results are demonstrated to validate the proposed method of controllers. The experimental results carried from norms and standard references are given to illustrate the efficiency and the benefits of the proposed calibration and the various stages of implementation of this method.
Keywords :
calibration; flow control; flow measurement; measurement systems; metering; petroleum industry; sensors; control flow measurement system; metering system control; metrological control; oil industry; sensor calibration; sensory instrument calibration; Calibration; Fluid flow measurement; Temperature measurement; Temperature sensors; Transmitters; Turbines; control; error; measurement; metering; sensor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference and Exposition (PEMC), 2014 16th International
Conference_Location :
Antalya
Type :
conf
DOI :
10.1109/EPEPEMC.2014.6980617
Filename :
6980617
Link To Document :
بازگشت