DocumentCode
1830808
Title
Optimising dynamically positioned vessel power systems using advanced converter control
Author
Stephens, Richard I. ; Childs, Jon F.
Author_Institution
Converteam UK Ltd., Rugby, UK
fYear
2010
fDate
7-10 Sept. 2010
Firstpage
1
Lastpage
6
Abstract
The paper describes the requirements for fault tolerance in the power systems of dynamically positioned vessels. The short-comings of diode bridge rectifiers in this regard are highlighted. The active front end converter is introduced and a further improvement in fault tolerance is shown to be available from dual active front end. This novel concept gives improved options for reducing the installed thrust or installed generation while continuing to meet classification society rules.
Keywords
diodes; fault tolerance; marine vehicles; power convertors; power system control; rectifiers; advanced converter control; classification society rules; diode bridge rectifiers; dynamically positioned vessels; fault tolerance; power systems; Dynamic positioning; converter control; fault tolerant control; marine power systems;
fLanguage
English
Publisher
iet
Conference_Titel
Control 2010, UKACC International Conference on
Conference_Location
Coventry
Electronic_ISBN
978-1-84600-038-6
Type
conf
DOI
10.1049/ic.2010.0418
Filename
6490876
Link To Document