• DocumentCode
    1831272
  • Title

    Registration in digital subtraction angiography using multiple ROI´s

  • Author

    Bao, Lei ; Sachs, Peter B. ; Wilson, David L.

  • Author_Institution
    Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH, USA
  • fYear
    1994
  • fDate
    3-6 Nov 1994
  • Firstpage
    502
  • Abstract
    Describes a method for using multiple regions of interest to register the digital subtraction angiography images. For each region of interest (ROI) placed on the mask image, similarity measures are optimized to determine the best sub-pixel x and y shifts. A figure of merit is calculated for each ROI and used to determine the best pixel shift vector for the entire image. Preliminary results indicate that the method is robust
  • Keywords
    diagnostic radiography; image registration; medical image processing; best pixel shift vector; digital subtraction angiography registration; figure of merit; mask image; medical diagnostic imaging; optimized similarity measures; region of interest; subpixel x shifts; subpixel y shifts; Angiography; Biomedical engineering; Biomedical imaging; Biomedical measurements; Blood vessels; Degradation; Image quality; Pixel; Robustness; Streaming media; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    0-7803-2050-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1994.411933
  • Filename
    411933