DocumentCode
1833127
Title
Dynamic cardiac SPECT with Tc-99m Teboroxime: compensation for rapid myocardial washout and high liver uptake
Author
Chen, Ji ; Galt, James R. ; Aarsvold, John N. ; Krawczynska, Elzbieta G. ; Alazraki, Naomi P. ; Zafari, A. Maziar ; Faber, Tracy L. ; Garcia, Ernest V.
Volume
5
fYear
2003
fDate
19-25 Oct. 2003
Firstpage
3155
Abstract
The quality of a Teboroxime single photon emission computed tomography (SPECT) study can be degraded by Teboroxime´s rapid myocardial washout and high liver uptake. Described is the use of a fast-fanning acquisition protocol and nonlinear regression with distance penalty (NLRDP) to compensate for the two effects. Tl-201/conventional single-rotation Sestamibi (MIBI) and Tl-201/dynamic fast-fanning Teboroxime (TEBO) rest/stress acquisitions were conducted on 18 subjects. TEBO reconstructions were processed by NLRDP using group-averaged kinetics to separate the images into liver, myocardium, and background compartments. Re-projections of each compartment were registered with the measured projections, allowing the extraction of the patient-specific kinetics. NLRDP identified defects (abnormal myocardium) with different kinetics from normal tissue by differences in the kinetics of the defect pixels. Enhanced-TEBO (E-TEBO) images were produced by using the kinetic curves to calculate the Teboroxime concentration in each pixel at the time of expected peak myocardial uptake and omitting the liver compartment. Total impaired and reversible myocardial mass were computed for the MIBI, TEBO, and E-TEBO images using the Emory Cardiac Toolbox. Regression and correlation analyses of these quantitative indices indicate that Teboroxime SPECT can produce similar results as Sestamibi SPECT if E-TEBO images are generated.
Keywords
biological tissues; cardiovascular system; correlation methods; data acquisition; haemorheology; image enhancement; image reconstruction; image registration; liver; medical image processing; regression analysis; single photon emission computed tomography; Emory Cardiac Toolbox; Tl-201/conventional single-rotation Sestamibi; Tl-201/dynamic fast-fanning Teboroxime rest/stress acquisitions; correlation analysis; distance penalty; dynamic cardiac SPECT; fast-fanning acquisition protocol; group-averaged kinetics; high Tc-99m Teboroxime liver uptake; image enhancement; image reconstruction; image registration; nonlinear regression analysis; normal tissue; patient-specific kinetics; rapid Tc-99m Teboroxime myocardial washout; single photon emission computed tomography; Degradation; Image analysis; Image reconstruction; Kinetic theory; Liver; Myocardium; Pixel; Protocols; Single photon emission computed tomography; Stress;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8257-9
Type
conf
DOI
10.1109/NSSMIC.2003.1352566
Filename
1352566
Link To Document