• DocumentCode
    1833448
  • Title

    Diffraction enhanced breast imaging: assessment of realistic system requirements to improve the diagnostic capabilities of mammography

  • Author

    Griffiths, Jennifer A. ; Royle, Gary J. ; Speller, Robert D. ; Horrocks, Julie A. ; Olivo, Alessandro ; Pani, Silvia ; Longo, Renata ; Spencer, Simon H. ; Robbins, Mark S. ; Clifford, Damian P. ; Hanby, Andrew M.

  • Author_Institution
    Dept. of Med. Phys. & Bioeng., Univ. Coll. London, UK
  • Volume
    5
  • fYear
    2003
  • fDate
    19-25 Oct. 2003
  • Firstpage
    3230
  • Abstract
    A detectable difference in X-ray diffraction data of healthy and diseased breast tissues has been observed. This information can be used to generate images with a higher contrast than that of conventional transmission mammography. A diffraction enhanced breast imaging (DEBI) system that simultaneously combines transmission and diffraction breast images is currently being developed. This paper presents the imaging system requirements for a clinical DEBI system. The DEBI imaging system employs a phosphor coated L3Vision CCD camera. The DEBI principle has been assessed at the SYRMEP synchrotron beamline (Elettra, Trieste) and with a purpose built mammographic X-ray imaging unit. Diffraction enhanced images have been obtained of realistic breast tissue phantoms, consisting of 4 cm thick slabs of excised breast tissue containing embedded carcinomas. The images were obtained at pre-determined momentum transfer values, allowing some tissue characterization to be achieved during imaging, as well as optimizing image contrast This paper presents the current state of the project. The spatial resolution of the diffraction images have been studied using test phantoms and suggestions are made for the collimation systems necessary for a clinical system. A correction procedure applied to the diffraction images is also presented.
  • Keywords
    biological organs; cancer; image enhancement; image resolution; mammography; medical image processing; phantoms; tumours; 4 cm; SYRMEP synchrotron beamline; collimation systems; diagnostic mammography; diffraction enhanced breast imaging; diseased breast tissues; embedded carcinomas; healthy breast tissues; images contrast; imaging system requirements; momentum transfer values; phosphor coated L3Vision CCD camera; realistic breast tissue phantoms; spatial resolution; Breast tissue; Image generation; Imaging phantoms; Mammography; Optical imaging; Phosphors; X-ray detection; X-ray detectors; X-ray diffraction; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2003 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8257-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2003.1352586
  • Filename
    1352586