• DocumentCode
    1833884
  • Title

    Tracking MOV operability under degraded voltage condition by periodic test measurements

  • Author

    Hussain, B. ; Behera, A.K. ; Alsammarae, A.J.

  • Author_Institution
    KCI Eng. Consultants, Downers Grove, IL, USA
  • Volume
    2
  • fYear
    1996
  • fDate
    2-9 Nov 1996
  • Firstpage
    979
  • Abstract
    The purpose of this paper is to develop a methodology for evaluating the operability of Alternating Current (AC) Motor Operated Valve (MOV) under degraded voltage condition, based on the seating parameter measured during surveillance/testing. This approach will help resolve Nuclear Regulatory Commission´s (NRC´s) concern on verifying the AC MOV´s design basis capability through periodic testing
  • Keywords
    valves; alternating current motor operated valve; degraded voltage condition; motor operated valve operability; periodic test measurements; periodic testing; seating parameter; AC motors; Current measurement; Degradation; Nuclear power generation; Surveillance; Switches; Testing; Torque; Valves; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.591513
  • Filename
    591513