DocumentCode :
1834226
Title :
Calibration method of amplitude and phase consistency of digital variable polarization radar receiving system
Author :
Liu, Jianxun ; Yu, Xiang ; Liang, Chaojie ; Sun, Ke ; Sun, Houjun
Author_Institution :
Sch. of Inf. & Electron., Beijing Inst. of Technol., Beijing, China
fYear :
2011
fDate :
22-25 May 2011
Firstpage :
44
Lastpage :
47
Abstract :
In order to calibrate the consistency of the amplitude and phase of four-channel digital variable polarization monopulse radar receiving system, a calibration method based on exterior space calibration is proposed. Making use of this method, author completes the calibration in the darkroom. After calibration, the experimental results show that in receiving pattern the polarization purity, null depth of difference beam and sidelobe balance are improved. The results demonstrate the method is correct and feasible.
Keywords :
electromagnetic wave polarisation; radar signal processing; amplitude consistency; calibration method; exterior space calibration; four channel digital variable polarization; monopulse radar receiving system; phase consistency; polarization purity; sidelobe balance; Calibration; Polarization; Radar; Radar antennas; Receiving antennas; Transmitting antennas; Amplitude-phase consistency; DBF; calibration; variable polarization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Technology & Computational Electromagnetics (ICMTCE), 2011 IEEE International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-8556-7
Type :
conf
DOI :
10.1109/ICMTCE.2011.5915162
Filename :
5915162
Link To Document :
بازگشت