DocumentCode :
1835345
Title :
Ultrasound Emitter Localization in Heterogeneous Media
Author :
Fluckiger, M. ; Nelson, B.J.
Author_Institution :
ETH Zurich, Zurich
fYear :
2007
fDate :
22-26 Aug. 2007
Firstpage :
2867
Lastpage :
2870
Abstract :
A novel algorithm to accurately determine the location of an ultrasound source within heterogeneous media is presented. The method obtains a small spacial error of 748 mumplusmn310 mum for 100 different measurements inside a circular area with 140 mm diameter. The new algorithm can be used in targeted drug delivery for cancer therapies as well as to accurately locate any kind of ultrasound sources in heterogeneous media, such as ultrasonically marked medical devices or tumors.
Keywords :
biomedical ultrasonics; cancer; drug delivery systems; tumours; cancer therapies; heterogeneous media; targeted drug delivery; tumors; ultrasonically marked medical devices; ultrasound emitter localization; Acoustic measurements; Biomedical imaging; Cancer; Minimally invasive surgery; Neoplasms; Nonhomogeneous media; Target tracking; Targeted drug delivery; Ultrasonic imaging; Ultrasonic variables measurement; Algorithms; Antineoplastic Agents; Drug Delivery Systems; Finite Element Analysis; Humans; Neoplasms; Ultrasonics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location :
Lyon
ISSN :
1557-170X
Print_ISBN :
978-1-4244-0787-3
Type :
conf
DOI :
10.1109/IEMBS.2007.4352927
Filename :
4352927
Link To Document :
بازگشت