DocumentCode
1835790
Title
Point-of-Care Noninvasive Hemoglobin Determination Using Fiber Optic Reflectance Spectroscopy
Author
Jay, G.D. ; Racht, J. ; McMurdy, J. ; Mathews, Z. ; Hughes, A. ; Suner, S. ; Crawford, G.
Author_Institution
Brown Univ., Providence
fYear
2007
fDate
22-26 Aug. 2007
Firstpage
2932
Lastpage
2935
Abstract
Study objective: rapidly identifying anemia through qualitative observation of the palpebral conjunctiva for pallor is standard medical practice. We report on the ability of using a fiber optic array probe to collect diffusely reflected light from the palpebral conjunctiva and measure hemoglobin concentration noninvasively. Patients (N=102) admitted to the emergency department and receiving a complete blood count (CBQ were enrolled as a convenience set. The tarsal plate was exposed by averting the lower eyelid and illuminated with a white LED while diffusely reflected light was collected using a fiber optic probe and commercial grating spectrometer. Spectra were analyzed using partial least squares regression to extract hemoglobin concentration information and compare to the CBC result. The probe and algorithm demonstrated correlation coefficient of r = 0.82 and standard error of 1.05 g/dL compared to invasive CBC test. Experimental error is due to variability in distance and position of the probe relative to the conjunctiva. This technique has shown the ability to measure total hemoglobin noninvasively and in real-time at the point-of-care using diffuse reflectance spectroscopy of the tarsal plate, leading to potential inclusion of this class of device as a triage centric tool to identify anemia appearing with internal hemorrhage or other acute conditions.
Keywords
biomedical optical imaging; blood; optical fibres; patient diagnosis; proteins; reflectivity; anemia; commercial grating spectrometer; complete blood count; diffuse reflectance spectroscopy; fiber optic array probe; fiber optic reflectance spectroscopy; hemoglobin concentration; internal hemorrhage; palpebral conjunctiva; partial least squares regression; point-of-care noninvasive hemoglobin determination; tarsal plate; Blood; Eyelids; Fiber gratings; Information analysis; Light emitting diodes; Optical arrays; Optical fibers; Probes; Reflectivity; Spectroscopy; Adolescent; Adult; Aged; Aged, 80 and over; Algorithms; Conjunctiva; Female; Fiber Optic Technology; Hemoglobins; Humans; Male; Middle Aged; Optical Fibers; Point-of-Care Systems; Prospective Studies; Sensitivity and Specificity; Spectrum Analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location
Lyon
ISSN
1557-170X
Print_ISBN
978-1-4244-0787-3
Type
conf
DOI
10.1109/IEMBS.2007.4352943
Filename
4352943
Link To Document