  • Title

    Ultrasonic interstitial heating in phantoms

  • Author

    Jarosz, Boguslaw J.

  • Author_Institution
    Dept. of Phys., Carleton Univ., Ottawa, Ont., Canada
  • fYear
    1989
  • fDate
    9-12 Nov 1989
  • Firstpage
    1451
  • Abstract
    Interstitial heating was achieved with an ultrasonic applicator made of an acoustic waveguide attached to a planar piezoelectric transducer, operated at about 1 MHz. A hyperthermia of 6.5-13.5°C was observed in two phantoms. After a linear initial rise, the temperature reached a plateau. The final temperature depends on a power applied, initial rate of heating, and, to a smaller degree, on the type of phantom. An interpretation, of the results based on the Hankel integral solution to the heat equation is presented
  • Keywords
    biomedical ultrasonics; biothermics; radiation therapy; 1 MHz; Hankel integral solution; acoustic waveguide; heat equation; heating rate; phantoms; planar piezoelectric transducer; Acoustic waveguides; Acoustic waves; Applicators; Heating; Hyperthermia; Imaging phantoms; Integral equations; Piezoelectric transducers; Planar waveguides; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
  • Conference_Location
    Seattle, WA
  • Type

    conf

  • DOI
    10.1109/IEMBS.1989.96284
  • Filename
    96284