Title :
Comparison between shifted Spearman rank correlation test and SPM in fMRI
Author :
Dewalle, A.S. ; Betrouni, N. ; Steinling, M. ; Vermandel, Maximilien ; Rousseau, J. ; Vasseur, Christian
Author_Institution :
Lille 2 Univ., Lille
Abstract :
A new improving method to compute Spearman rank correlation test has been developed. This method is based on the use of a response to stimulation delay referred by many authors. Visual results tend to prove the method efficiency which is confirmed by obtained overlap rates; moreover this method can easily be adapted in a clinical context.
Keywords :
biomedical MRI; correlation theory; medical image processing; statistical testing; fMRI; functional magnetic resonance imaging; image preprocessing; shifted Spearman rank correlation test; stimulation delay; Epilepsy; Fingers; Foot; Hospitals; Magnetic resonance imaging; Nuclear medicine; Scanning probe microscopy; Surgery; Testing; Thumb; Adult; Algorithms; Brain Mapping; Computer Simulation; Data Interpretation, Statistical; Female; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging; Male; Models, Neurological; Models, Statistical; Reproducibility of Results; Sensitivity and Specificity; Statistics, Nonparametric; Subtraction Technique;
Conference_Titel :
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location :
Lyon
Print_ISBN :
978-1-4244-0787-3
DOI :
10.1109/IEMBS.2007.4353061