• DocumentCode
    1838464
  • Title

    Comparison between shifted Spearman rank correlation test and SPM in fMRI

  • Author

    Dewalle, A.S. ; Betrouni, N. ; Steinling, M. ; Vermandel, Maximilien ; Rousseau, J. ; Vasseur, Christian

  • Author_Institution
    Lille 2 Univ., Lille
  • fYear
    2007
  • fDate
    22-26 Aug. 2007
  • Firstpage
    3400
  • Lastpage
    3403
  • Abstract
    A new improving method to compute Spearman rank correlation test has been developed. This method is based on the use of a response to stimulation delay referred by many authors. Visual results tend to prove the method efficiency which is confirmed by obtained overlap rates; moreover this method can easily be adapted in a clinical context.
  • Keywords
    biomedical MRI; correlation theory; medical image processing; statistical testing; fMRI; functional magnetic resonance imaging; image preprocessing; shifted Spearman rank correlation test; stimulation delay; Epilepsy; Fingers; Foot; Hospitals; Magnetic resonance imaging; Nuclear medicine; Scanning probe microscopy; Surgery; Testing; Thumb; Adult; Algorithms; Brain Mapping; Computer Simulation; Data Interpretation, Statistical; Female; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging; Male; Models, Neurological; Models, Statistical; Reproducibility of Results; Sensitivity and Specificity; Statistics, Nonparametric; Subtraction Technique;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
  • Conference_Location
    Lyon
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-0787-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2007.4353061
  • Filename
    4353061