Cuffless and Noninvasive Measurement of Systolic Blood Pressure, Diastolic Blood Pressure, Mean Arterial Pressure and Pulse Pressure using Radial Artery Tonometry Pressure Sensor with Concept of Korean Traditional Medicine
Author :
Mikyoung Park ; Hee Jung Kang ; Young Huh ; Kyung-Chul Kim
Author_Institution :
Korea Electrotechnol. Res. Inst., Changwon
fYear :
2007
fDate :
22-26 Aug. 2007
Firstpage :
3597
Lastpage :
3600
Abstract :
Parameters for noninvasive diagnosis and monitoring of cardiovascular disease. We developed a new method to measure blood pressure (BP) noninvasively without cuff. In Korean traditional medicine, the degree of the pulse depth is one of the important criteria to diagnosis. We combined this concept with pulse wave analysis. With clinical data obtained from 163 subjects, we selected APm (applied pressure which has a maximum value of pulse wave), elasticity of wrist tissue, depth of blood vessel, cardiac output and h1 as parameters to estimate blood pressure. And with the parameters, we induced multi regression equation of systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP). And the probabilities of these parameters to explain SBP, DBP, and MAP were 89.5%, 91.1% and 94.6%, respectively. To estimate PP, we added hi to the parameters to explain PP was 97.5%. We compared the estimated SBP, DBP, MAP and PP through the multiple regression equations to the actual measured SBP, DBP, MAP and PP through the wrist type BP meter. Differences were (plusmn SD) 0.38 plusmn 9.95, -1.0 plusmn 8.2, 0.02 plusmn 6.9 and 0.05 plusmn 5.9 mmHg for SBP, DBP, MAP and PP, respectively. According to the American National Standard for Electronic or Automated Sphygmomanometers, the mean difference (MD) should be plusmn 5 mmHg or less with a standard deviation (SD) of plusmn 8 mmHg or less. Hence, the results of MAP and PP were within the limits for the AAMI SP 10 criteria and the results of SBP and DBP were not within the limits for the AAMI SP 10 criteria. The preliminary results indicate the results are quite reliable and promising.
Keywords :
biomechanics; blood pressure measurement; blood vessels; cardiovascular system; diseases; manometers; medical signal processing; patient diagnosis; patient monitoring; pressure sensors; regression analysis; Korean traditional medicine; automated sphygmomanometers; blood vessel depth; cardiac output; cardiovascular disease monitoring; diastolic blood pressure measurement; mean arterial pressure measurement; multiple regression equations; noninvasive diagnosis; pulse pressure; pulse wave analysis; radial artery tonometry pressure sensor; systolic blood pressure measurement; wrist tissue elasticity; Arteries; Biomedical monitoring; Blood pressure; Cardiovascular diseases; Condition monitoring; Equations; Noninvasive treatment; Pressure measurement; Pulse measurements; Wrist; Blood Pressure; Blood Pressure Determination; Diagnosis, Computer-Assisted; Diastole; Humans; Korea; Manometry; Medicine, East Asian Traditional; Palpation; Pulse; Radial Artery; Reproducibility of Results; Sensitivity and Specificity; Systole;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location :
Lyon
ISSN :
1557-170X
Print_ISBN :
978-1-4244-0787-3
Type :
conf
DOI :
10.1109/IEMBS.2007.4353109
Filename :
4353109
Link To Document :
بازگشت