DocumentCode :
1839892
Title :
Steady-state frequency analysis of the “LLC” resonant inverter for induction heating
Author :
Espí, J.M. ; Dede, E.J. ; Ferreres, A. ; García, R.
Author_Institution :
Electron. Dept., Valencia Univ., Spain
fYear :
1996
fDate :
14-17 Oct 1996
Firstpage :
22
Lastpage :
28
Abstract :
In this paper, the main steady-state frequency properties of the LLC circuit are described. The advantage of its use on induction heating applications is proved, in contrast with the SRI (series resonant inverter). This analysis will allow the future design of a frequency control strategy for the inverter. Finally, a simple design algorithm is proposed, which satisfies the power specifications and limits the stress current in the switches
Keywords :
frequency control; induction heating; invertors; resonant power convertors; LLC resonant inverter; design algorithm; frequency control strategy; induction heating; power specifications; series resonant inverter; steady-state frequency analysis; steady-state frequency properties; switch stress current limiting; Circuits; Frequency control; Impedance; Q factor; Resonance; Resonant inverters; Steady-state; Stress; Switches; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Congress, 1996. Technical Proceedings. CIEP '96., V IEEE International
Conference_Location :
Cuernavaca
Print_ISBN :
0-7803-3633-X
Type :
conf
DOI :
10.1109/CIEP.1996.618509
Filename :
618509
Link To Document :
بازگشت