DocumentCode :
1840118
Title :
Resolution and signal loss in acoustic microscopy of encapsulated IC packages
Author :
Canumalla, Sridhar ; Oravecz, Michael G. ; Kessler, Lawrence W.
Author_Institution :
Sonoscan Inc., Bensenville, IL, USA
fYear :
1998
fDate :
25-28 May 1998
Firstpage :
962
Lastpage :
968
Abstract :
This paper examines the degradation of resolution and signal strength in pulsed acoustic microscopy of plastic encapsulated ICs. The effects of attenuation of ultrasound in water and plastic encapsulants, and transducer characteristics such as bandwidth, focal length and center frequency, are investigated. Ignoring the consequences of attenuation or spectral characteristics of the transducer could lead to overestimation of the resolution by as much as a factor of two in high frequency inspection. The novel procedure presented in this paper can not only help predict a realistic resolution, but can also be applied in selecting the optimum combination of transducer characteristics for specific materials
Keywords :
acoustic microscopy; inspection; integrated circuit packaging; plastic packaging; ultrasonic applications; bandwidth; center frequency; encapsulated IC packages; focal length; high frequency inspection; plastic encapsulated ICs; pulsed acoustic microscopy; resolution; signal loss; transducer characteristics; Acoustic pulses; Acoustic transducers; Attenuation; Degradation; Frequency; Microscopy; Plastics; Signal resolution; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic Components & Technology Conference, 1998. 48th IEEE
Conference_Location :
Seattle, WA
ISSN :
0569-5503
Print_ISBN :
0-7803-4526-6
Type :
conf
DOI :
10.1109/ECTC.1998.678825
Filename :
678825
Link To Document :
بازگشت