Resolution and signal loss in acoustic microscopy of encapsulated IC packages
Author
Canumalla, Sridhar ; Oravecz, Michael G. ; Kessler, Lawrence W.
Author_Institution
Sonoscan Inc., Bensenville, IL, USA
fYear
1998
fDate
25-28 May 1998
Firstpage
962
Lastpage
968
Abstract
This paper examines the degradation of resolution and signal strength in pulsed acoustic microscopy of plastic encapsulated ICs. The effects of attenuation of ultrasound in water and plastic encapsulants, and transducer characteristics such as bandwidth, focal length and center frequency, are investigated. Ignoring the consequences of attenuation or spectral characteristics of the transducer could lead to overestimation of the resolution by as much as a factor of two in high frequency inspection. The novel procedure presented in this paper can not only help predict a realistic resolution, but can also be applied in selecting the optimum combination of transducer characteristics for specific materials
Keywords
acoustic microscopy; inspection; integrated circuit packaging; plastic packaging; ultrasonic applications; bandwidth; center frequency; encapsulated IC packages; focal length; high frequency inspection; plastic encapsulated ICs; pulsed acoustic microscopy; resolution; signal loss; transducer characteristics; Acoustic pulses; Acoustic transducers; Attenuation; Degradation; Frequency; Microscopy; Plastics; Signal resolution; Ultrasonic imaging; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Components & Technology Conference, 1998. 48th IEEE
Conference_Location
Seattle, WA
ISSN
0569-5503
Print_ISBN
0-7803-4526-6
Type
conf
DOI
10.1109/ECTC.1998.678825
Filename
678825
Link To Document