DocumentCode :
1840320
Title :
In-situ CMP copper endpoint control system
Author :
Allen, Ron ; Chen, Charles ; Trikas, Tom ; Lehman, Kurt ; Shinagawa, Robert ; Bhaskaran, Vijay ; Stephenson, Brian ; Watts, David
Author_Institution :
Mercury Div., KLA-Tencor Corp., Milpitas, CA, USA
fYear :
2001
fDate :
2001
Firstpage :
391
Lastpage :
394
Abstract :
Describes the design, operation, and algorithms for an in-situ CMP endpoint detection and control system, with particular emphasis on copper polishing. The system´s eddy current-based sensor gives absolute surface metal thickness. Its multi-angle reflectometer gives eight optical reflectance measurements. The endpointer improves on existing sensors and techniques in several ways. It can process reflectance traces individually according to their endpoint sensitivity, which applies to dielectric polishing and copper barrier removal processes. Also, it merges reflectance signals for higher signal-to-noise ratios, which benefits copper CMP. Finally, the system can fuse the reflectance data with thickness readings for more robust endpoint detection
Keywords :
chemical mechanical polishing; copper; eddy current testing; integrated circuit interconnections; process control; process monitoring; reflectometry; CMP; Cu; absolute surface metal thickness; barrier removal processes; copper polishing; dielectric polishing; eddy current-based sensor; endpoint control system; endpoint detection; endpoint sensitivity; multi-angle reflectometer; optical reflectance measurements; reflectance traces; signal-to-noise ratios; thickness readings; Algorithm design and analysis; Control systems; Copper; Dielectric measurements; Fuses; Optical sensors; Reflectivity; Robustness; Sensor systems; Signal to noise ratio;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Semiconductor Manufacturing Symposium, 2001 IEEE International
Conference_Location :
San Jose, CA
Print_ISBN :
0-7803-6731-6
Type :
conf
DOI :
10.1109/ISSM.2001.962997
Filename :
962997