• DocumentCode
    1841129
  • Title

    Improvement of 300mm FOUP mini-environment

  • Author

    Seita, Hisaharu ; Fujii, Atsuhiro ; Suzuki, Tatsuya ; Kimoto, Shinyo ; Shippou, Osamu ; Fujiwara, Keiji ; Tokunaga, Kenji

  • Author_Institution
    Semicond. Leading Edge Technol. Inc., Yokohama, Japan
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    503
  • Lastpage
    506
  • Abstract
    Evaluates both mechanical and process characteristics of FOUPs (front opening unifed pods) and improves performance through feedback to suppliers. Issues of FOUPs are as follows.: dimensions; FOUP/LP interoperability; particle contamination; organic contamination; and drying defectiveness We have developed 3-dimensional FOUP measuring equipment with Nikon Instech Co. (Nexiv450N) and measured critical dimensions like wafer teeth height, Y52, and latch key hole position. With the Nexiv450N we could take the dimensions of each FOUP to their nominal values. It´s important to align the dimension of the FOUP to realize FOUP/load port interoperability
  • Keywords
    clean rooms; conveyors; drying; integrated circuit manufacture; 300 mm; FOUP mini-environment; Nexiv450N; Nikon Instech; critical dimensions; dimensions; drying defectiveness; front opening unifed pods; latch key hole position; load port interoperability; mechanical characteristics; organic contamination; particle contamination; process characteristics; wafer teeth height; Cleaning; Contamination; Feedback; Lead compounds; Particle measurements; Pollution measurement; Position measurement; Rails; Shape measurement; Teeth;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Semiconductor Manufacturing Symposium, 2001 IEEE International
  • Conference_Location
    San Jose, CA
  • Print_ISBN
    0-7803-6731-6
  • Type

    conf

  • DOI
    10.1109/ISSM.2001.963025
  • Filename
    963025