• DocumentCode
    1845213
  • Title

    Partial discharge testing of HV wiring harness for airborne displays

  • Author

    Horwath, J. ; Schweickart, D. ; Rhoads, G. ; Fuchs, S. ; Bapu, P. ; Dunbar, W.

  • Author_Institution
    Wright Lab., Wright-Patterson AFB, OH, USA
  • fYear
    1994
  • fDate
    23-26 Oct 1994
  • Firstpage
    149
  • Lastpage
    154
  • Abstract
    More flexible helmet-mounted CRTs are now being developed, presenting new design challenges. For example, high voltage leads for helmet-mounted displays must incorporate a quick release, load-break mechanism to accommodate pilot ejection. The potential presence of flammable vapors resulted in an arc-suppressing, quick-disconnect, connector design which opens the high voltage via hermetically sealed contacts. The sealed contacts contain any arcing and break the circuit before the connector separates. A prototype harness for a helmet mounted display (HMD) and tracker has been designed jointly by the University of Dayton Research Institute and Reynolds Inc. under the sponsorship of Armstrong Laboratory. The harness routes two 13.5 kilovolt rated direct current leads along with other wiring via the quick-disconnect connector. The high voltage and compact design motivate concerns about partial discharge degradation of the insulation, particularly at sub-atmospheric pressures. The harness has been tested at simulated altitudes up to 70000 feet, at operating voltage. Results of the testing at Wright Laboratory are presented
  • Keywords
    aircraft displays; 13.5 kV; 70000 feet; FEP insulation; HV wiring harness; SF6 filled circuit breaker; airborne displays; arc-suppressing quick-disconnect connector design; circuit breaker; corona inception voltage; direct current leads; fluorinated ethylene propylene copolymer; helmet-mounted CRTs; helmet-mounted displays; hermetically sealed contacts; high voltage interruption mechanism; high voltage leads; partial discharge testing; pilot ejection; quick release load-break mechanism; subatmospheric pressure; tactical aircraft; Cathode ray tubes; Connectors; Contacts; Displays; Flammability; Lead; Partial discharges; Testing; Voltage; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1994., IEEE 1994 Annual Report., Conference on
  • Conference_Location
    Arlington, TX
  • Print_ISBN
    0-7803-1950-8
  • Type

    conf

  • DOI
    10.1109/CEIDP.1994.591734
  • Filename
    591734