DocumentCode
1845284
Title
An Automatic Calibration Approach For Left Ventricular Volume Assessment
Author
Beatrice, P. ; Regis, V. ; Philippe, D. ; Remy, P. ; Francoise, P. ; Gerard, F.
Author_Institution
Univ. Lyon 1, Lyon
fYear
2007
fDate
22-26 Aug. 2007
Firstpage
4460
Lastpage
4463
Abstract
The development of interventional procedures in the catheterization laboratory drives the introduction of simple, fast and accurate quantification methods. Quantification is used to evaluate the volume of the left ventricle but also for choosing the size of a balloon or a stent during the percutaneous coronary angioplasty procedure. The objective of the calibration procedure is to establish the relation between the true size of the analyzed organ and its apparent size in the image. This calibration step aims at measuring the pixel size in mm. Traditional approach measures a known object on the image, but suffers from several limitations and constraints; in particular, the size of the reference object is often not exactly known. Besides, the therapeutic procedures are done in the continuity of the diagnosis and the physician has a very little amount of time to spend on the determination of the quantitative information like the chosen reference size. A new approach has been proposed, allowed by the introduction of the flat-panel technology and modern positioning systems. With the absence of distortion in the image and accurate knowledge of the system geometry, a model can be used to automatically identify the calibration factor using an additional input provided by the operator: the target organ height above the tabletop. The objective of our study was to estimate this input parameter in the particular case of the Left Ventricle (LV) volume angiographic computation. In this article, we compared two estimates of the LV center height and assessed their performances through the computation of the LV volume. We concluded on the reliability of the fully automatic calibration procedure.
Keywords
angiocardiography; blood vessels; calibration; cardiovascular system; surgery; angiographic computation; automatic calibration approach; catheterization; flat-panel technology; interventional procedures; left ventricular volume assessment; percutaneous coronary angioplasty; pixel size measurement; positioning systems; therapeutic procedures; Angioplasty; Calibration; Catheterization; Geometry; Image analysis; Laboratories; Parameter estimation; Particle measurements; Size measurement; Solid modeling; Angiography; Calibration; Female; Heart Ventricles; Humans; Male; Models, Biological; Organ Size;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location
Lyon
ISSN
1557-170X
Print_ISBN
978-1-4244-0787-3
Type
conf
DOI
10.1109/IEMBS.2007.4353329
Filename
4353329
Link To Document