• DocumentCode
    1845553
  • Title

    An intelligent flow sensor system with zero drift self calibration function

  • Author

    Dong, Ziqiang ; Huang, Qing-An ; Qin, Ming ; Shen, Guangping

  • Author_Institution
    Key Lab. of MEMS of Minist. of Educ., Southeast Univ., Nanjing, China
  • fYear
    2009
  • fDate
    18-21 Oct. 2009
  • Firstpage
    28
  • Lastpage
    31
  • Abstract
    A double operation modes intelligent flow sensor system with zero drift self calibration function is reported in this paper. In order to improve the sensitivity and the stability, the sensor chip was fabricated on ceramic substrate, and using lift off process to pattern the heater and sensing detectors. The heating and sensing elements are Ti/Pt resistors and with the temperature coefficient is 3050 ppm, Ti layer was introduced to improve the adhesion between Pt layer and the front surface of ceramic substrate. Direct Chip Attach(DCA) packaging was adopted to protect the chip and the circuits below it. The Constant Temperature Difference(CTD) control mode is introduced to detect high velocity flow, while calorimetric operation mode is used for low flow velocity measurement. The sensor is designed to operate in the two modes at the same time, and their outputs are detected by a Micro Controller Unit(MCU). Because the calorimetric control mode presents low zero point drift, it is used to calibrate the zero point of CTD control mode. The intelligent sensor system was tested in flow tunnel, if the calorimetric control mode shows the flow velocity less than 20 m/s, the MCU computes the difference of the two modes outputs and gets a calibration voltage to change the zero point of the CTD control mode. When the calorimetric control mode shows the flow velocity higher than 20 m/s, the last calibration zero point of the CTD control mode is considered as a accurate value. After calibration, the relative error of flow velocity measurement is less than 5% from 0 m/s to 60 m/s.
  • Keywords
    adhesion; calorimetry; ceramics; electronics packaging; flow sensors; intelligent sensors; resistors; Pt layer; adhesion; calorimetric control mode; calorimetric operation mode; ceramic substrate; constant temperature difference control mode; direct chip attach packaging; flow tunnel; flow velocity measurement; heater detector; intelligent flow sensor system; low flow velocity measurement; microcontroller unit; resistors; sensing detector; temperature coefficient; zero drift self calibration function; Artificial neural networks; Ceramics; Fabrication; double modes; flow speed; intelligent sensor system; self calibration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nano/Molecular Medicine and Engineering (NANOMED), 2009 IEEE International Conference on
  • Conference_Location
    Tainan
  • Print_ISBN
    978-1-4244-5528-7
  • Type

    conf

  • DOI
    10.1109/NANOMED.2009.5559124
  • Filename
    5559124