DocumentCode :
1846106
Title :
The aluminum flat heat pipe using cyclopentane as working fluid
Author :
Shimura, Takahiro ; Sho, Hitoshi ; Nakamura, Yoshio
Author_Institution :
Ecology & Energy Lab., Furukawa Electr. Co. Ltd., Hiratsuka, Japan
fYear :
2002
fDate :
2002
Firstpage :
224
Lastpage :
229
Abstract :
Aluminum flat heat pipes are expected to be very useful for electronic components cooling because thin, light and bendable pipes are possible. However, there is a problem that conventional working fluids, such as freons (including not only CFCs but also HCFCs and HFCs), are harmful to the global environment. In this paper, cyclopentane application to aluminum heat pipes is discussed. First, thermal resistance in aluminum-cyclopentane heat pipes was evaluated as compared with aluminum-HCFC123 heat pipes. Secondary, the long time reliability in aluminum-cyclopentane heat pipes was compared with that of aluminum-HCFC123. These evaluations showed the possibility of substitution for HCFC123 by cyclopentane and gave one answer to the working fluid problem in aluminum heat pipes.
Keywords :
aluminium; cooling; environmental factors; heat pipes; organic compounds; packaging; reliability; thermal resistance; Al flat heat pipes; CFCs; HCFCs; HFCs; cyclopentane working fluid; electronic components cooling; freons; global environment; long time reliability; thermal resistance; Aluminum; Containers; Cooling; Copper; Heat transfer; Hybrid fiber coaxial cables; Hydrocarbons; Resistance heating; Thermal resistance; Water heating;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Thermal and Thermomechanical Phenomena in Electronic Systems, 2002. ITHERM 2002. The Eighth Intersociety Conference on
ISSN :
1089-9870
Print_ISBN :
0-7803-7152-6
Type :
conf
DOI :
10.1109/ITHERM.2002.1012461
Filename :
1012461
Link To Document :
بازگشت