• DocumentCode
    1848067
  • Title

    Comparative analysis between two proposed uses of the line inter-phase transformer in 12 pulse three phase rectifiers

  • Author

    Munoz, B. Carlos A ; Barbi, Ivo

  • Author_Institution
    Fac. de Ingenieria, Los Andes Univ., Merida, Venezuela
  • fYear
    1996
  • fDate
    14-17 Oct 1996
  • Firstpage
    212
  • Lastpage
    216
  • Abstract
    In this paper a comparative study between two proposed uses of the line inter-phase transformer (LIT), as a passive solution to improve the input current shape in very high power three phase systems, is presented . By using the LIT, in 12 pulse operations, an input current shaping without the 5th and 7th harmonics is obtained. Experimental results, theoretical analysis and numerical simulation are presented to accomplish the comparison
  • Keywords
    harmonic distortion; power system harmonics; rectifying circuits; transformers; 12 pulse three phase rectifiers; input current shape; input current shaping; line inter-phase transformer; total harmonic distortion reduction; very high power three phase systems; Electrical equipment industry; Electronics industry; Inductors; Numerical simulation; Phase transformers; Power harmonic filters; Pulse shaping methods; Pulse transformers; Rectifiers; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Congress, 1996. Technical Proceedings. CIEP '96., V IEEE International
  • Conference_Location
    Cuernavaca
  • Print_ISBN
    0-7803-3633-X
  • Type

    conf

  • DOI
    10.1109/CIEP.1996.618540
  • Filename
    618540