Title :
Performance of a high current, low pressure hydrogen radial pseudospark switch
Author :
Cravey, W.R. ; Devlin, G.L. ; Savage, M.E. ; Simpson, W.W.
Author_Institution :
Tetra Corp., Albuquerque, NM, USA
fDate :
June 29 1997-July 2 1997
Abstract :
Tetra, under contract to Sandia National Laboratory has designed, built and tested a high current low pressure radial pseudospark switch. The new switch utilizes a diffuse radial discharge (from which the name radial pseudospark switch is derived) which greatly reduces electrode erosion and increased overall life-time. Switch testing was performed in two stages: low current testing at Tetra, and high current testing at Sandia. Low current tests were performed on the switch at voltage levels of 10-20 kV, peak currents of over 200 kA, and switched energies of 100 kJ. High currents tests were performed on the Sandia Switch Test Stand at energy levels of greater than 300 kJ and peak currents in excess of 500 kA.
Keywords :
electrodes; pulsed power switches; spark gaps; sparks; 10 to 20 kV; 100 kJ; 200 kA; 300 kJ; 500 kA; Sandia National Laboratory; Sandia Switch Test Stand; Tetra; diffuse radial discharge; electrode erosion reduction; high current; high current testing; low current testing; low pressure hydrogen; radial pseudospark switch; Costs; Electrodes; Hydrogen; Laser beams; Laser fusion; Life testing; Magnetic field measurement; Performance evaluation; Switches; Voltage;
Conference_Titel :
Pulsed Power Conference, 1997. Digest of Technical Papers. 1997 11th IEEE International
Conference_Location :
Baltimore, MA, USA
Print_ISBN :
0-7803-4213-5
DOI :
10.1109/PPC.1997.679346