Title :
Performance of the multi-pulse X-ray imaging system for the pulsed power hydrodynamic experiments at LANL
Author :
Obst, A.W. ; Fulton, D. ; King, N.S.P. ; Morgan, D. ; Oro, D. ; Platts, D. ; Sorenson, D.S. ; Stelts, M.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
fDate :
June 29 1997-July 2 1997
Abstract :
Pulsed power driven cylindrical shock physics experiments are being performed at the PEGASUS facility at Los Alamos National Laboratory. A time dependent, axial X-ray imaging capability forms a subset of the measurements to quantify material behavior during shock propagation. 20 ns pulsed W target X-ray sources with about 10 mR at 1 m form the backlighter. Inorganic scintillators generate time dependent, visible images, which are relayed to a shuttered, microchannel plate intensifier imaging system coupled to electronic video readouts. The dynamic range, sensitivity, scene contrast, and system spatial resolution are optimized to specific experiments via optimization of fluor response to both X-ray energy and light output time response. In addition, a series of calibration data are taken to permit characterizing density information through postevent image processing. This dataset includes flat field and step wedge images. The flat field is particularly important due to the relatively large spatial variation in the X-ray dose resulting from the close proximity (60 cm) of the source to the imager.
Keywords :
X-ray imaging; hydrodynamics; microchannel plates; power supplies to apparatus; pulse generators; pulsed power technology; shock waves; Los Alamos National Laboratory; PEGASUS facility; X-ray energy; backlighter; calibration data; cylindrical shock physics experiments; dynamic range; electronic video readouts; flat field images; fluor response optimisation; inorganic scintillators; light output time response; multi-pulse X-ray imaging system; postevent image processing; pulsed W target X-ray sources; pulsed power hydrodynamic experiments; scene contrast; sensitivity; shock propagation; shuttered microchannel plate intensifier imaging system; step wedge images; system spatial resolution; time dependent visible images; Dynamic range; Electric shock; Laboratories; Microchannel; Optical imaging; Physics; Pulse measurements; Relays; Time measurement; X-ray imaging;
Conference_Titel :
Pulsed Power Conference, 1997. Digest of Technical Papers. 1997 11th IEEE International
Conference_Location :
Baltimore, MA, USA
Print_ISBN :
0-7803-4213-5
DOI :
10.1109/PPC.1997.679372