Computation of the electric field around a wet polluted insulator by analytic and numerical techniques
Author :
Basappa, P. ; Lakdawala, V. ; Gerdin, G.
Author_Institution :
Norfolk State Univ., VA, USA
fYear :
2001
fDate :
2001
Firstpage :
564
Lastpage :
567
Abstract :
A benchmark problem of a cylindrical insulator with a wet and dry band is formulated. An analytic solution was obtained and numerically evaluated, and compared with the solution obtained from: (1) a finite-differencing technique; and (2) a commercially available finite-element software. The agreement between the solutions obtained from the three methods was found to be within 10 to 20%
Keywords :
electric fields; electrical engineering computing; finite difference methods; finite element analysis; flashover; insulator contamination; insulator testing; electric field calculations; finite-differencing technique; finite-element software; polluted outdoor insulation flashover; wet polluted cylindrical insulator; Conductivity; Dielectrics and electrical insulation; Electrodes; Environmentally friendly manufacturing techniques; Finite difference methods; Flashover; Geometry; Pollution; Resistors; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2001 Annual Report. Conference on
Conference_Location :
Kitchener, Ont.
Print_ISBN :
0-7803-7053-8
Type :
conf
DOI :
10.1109/CEIDP.2001.963606