• DocumentCode
    1851882
  • Title

    Three dimensional imaging of leakages from cylinderic microwave applicator

  • Author

    Ali, Shaima Mohammed

  • Volume
    3
  • fYear
    2003
  • fDate
    22-27 June 2003
  • Firstpage
    1095
  • Abstract
    The harmful effects of microwave radiation enforced specialists to study leakage from different forms of microwave applicators in order to save workers as well as users and professionals. In this paper, investigations are carried out to make three dimensional imaging of electromagnetic leakage from a cylindrical applicator. A suitable function for continuation and smoothing the samples is chosen, as well as a filter transfer function. The results of a computer simulation aimed at demonstrating the imaging technique are reported. The high resolution capability of this new mode of imaging is illustrated for a frequency of 2.45 GHz.
  • Keywords
    health hazards; image reconstruction; image resolution; microwave holography; microwave imaging; microwave measurement; 2.45 GHz; computer-aided image reconstruction; cylindrical microwave applicator; electromagnetic leakage; filter transfer function; high resolution imaging; microwave hologram; microwave leakage 3D imaging; microwave radiation harmful effects; sample continuation; sample smoothing; Applicators; Computer simulation; Electromagnetic radiation; Frequency; High-resolution imaging; Image resolution; Microwave filters; Microwave imaging; Smoothing methods; Transfer functions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation Society International Symposium, 2003. IEEE
  • Conference_Location
    Columbus, OH, USA
  • Print_ISBN
    0-7803-7846-6
  • Type

    conf

  • DOI
    10.1109/APS.2003.1220102
  • Filename
    1220102