• DocumentCode
    1851961
  • Title

    Pulse transformer R&D for NLC klystron pulse modulator

  • Author

    Akemoto, M. ; Gold, S. ; Krasnykh, A. ; Koontz, R.

  • Author_Institution
    Linear Accel. Center, Stanford Univ., CA, USA
  • Volume
    1
  • fYear
    1997
  • fDate
    June 29 1997-July 2 1997
  • Firstpage
    724
  • Abstract
    The authors have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and requires a larger core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250 ns and a pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests using a klystron load are also presented.
  • Keywords
    klystrons; load (electric); modulators; power supplies to apparatus; power transformers; pulse generators; pulse transformers; pulsed power technology; transformer cores; 250 ns; NLC klystron pulse modulator; R&D; core size; high voltage tests; klystron load; low distributed capacitance; low leakage inductance; pulse droop; pulse time-response; pulse transformer; pulsed power supply; rise time; secondary turns; simplified lumped circuit model; transmission characteristics; Capacitance; Circuits; Inductance; Klystrons; Pulse measurements; Pulse modulation; Pulse transformers; Testing; Transformer cores; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1997. Digest of Technical Papers. 1997 11th IEEE International
  • Conference_Location
    Baltimore, MA, USA
  • Print_ISBN
    0-7803-4213-5
  • Type

    conf

  • DOI
    10.1109/PPC.1997.679429
  • Filename
    679429