• DocumentCode
    1852002
  • Title

    Object imaging with a piezoelectric robotic tactile sensor

  • Author

    Dyson, Craig S. ; Yauilla, Nik C. ; Kolesar, Edward S., Jr.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Air Force Inst. of Technol., Wright-Patterson AFB, OH, USA
  • fYear
    1993
  • fDate
    24-28 May 1993
  • Firstpage
    41
  • Abstract
    A two-dimensional, electrically-multiplexed robotic tactile sensor was realized by coupling a piezoelectric polyvinylidene fluoride (PVDF) polymer film to a monolithic silicon integrated circuit (IC). The IC incorporates 64 sensor electrodes arranged in a symmetrical 8×8 matrix. Each electrode occupies a 400×400 μm square area, and they are separated from each other by 300 μm. A 40-μm thick piezoelectric PVDF polymer film was attached to the electrode array with an electrically non-conductive urethane adhesive. The response of the tactile sensor is linear for loads spanning 0.8 to 135 grams of force (gmf). The response bandwidth is 25 Hz, the hysteresis level is tolerable, and, for operation in the sensor´s linear range, taxel crosstalk is negligible. The historically persistent stability and response reproducibility limitation associated with piezoelectric-based tactile sensors has been solved by implementing a novel pre-charge voltage bias technique to initialize the pre- and post-load sensor responses. A rudimentary tactile object image measurement procedure for applied loads has been devised to recognize the silhouette of a sharp edge, square, trapezoid, isosceles triangle, circle, toroid, slotted screw, and cross-slotted screw
  • Keywords
    CMOS integrated circuits; electric sensing devices; image recognition; integrated circuit technology; piezoelectric transducers; polymer films; robots; tactile sensors; 25 Hz; 2D sensor; 40 mum; MOSFET amplifiers; PVDF; Si; circle; cross-slotted screw; electrically non-conductive urethane adhesive; electrically-multiplexed robotic tactile sensor; isosceles triangle; linear range; monolithic Si integrated circuit; piezoelectric polyvinylidene fluoride polymer film; piezoelectric robotic tactile sensor; pre-charge voltage bias; response bandwidth; response reproducibility; sharp edge; silhouette; square; stability; symmetrical 8×8 matrix; toroid; trapezoid; Coupling circuits; Electrodes; Fasteners; Force sensors; Monolithic integrated circuits; Polymer films; Robot sensing systems; Silicon; Symmetric matrices; Tactile sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Aerospace and Electronics Conference, 1993. NAECON 1993., Proceedings of the IEEE 1993 National
  • Conference_Location
    Dayton, OH
  • Print_ISBN
    0-7803-1295-3
  • Type

    conf

  • DOI
    10.1109/NAECON.1993.290890
  • Filename
    290890