• DocumentCode
    1854481
  • Title

    MEMS based computed tomographic scanner for border security

  • Author

    Arunachalam, K. ; Udpa, L. ; Udpa, S.S.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI
  • fYear
    2005
  • fDate
    22-25 May 2005
  • Lastpage
    5
  • Abstract
    High energy X-ray imaging is a well established-screening modality for large and high density cargo containers and vehicles at airports, seaports and border crossings. High energy X-rays are used for noninvasive detection of contraband goods and for curtailing illegal activities at the borders. The increased threat of global terrorism has led to the need for a non-intrusive imaging system that can yield high resolution images with reduced false alarms. In conventional X-ray systems, the constricted source detector arrangement and large container size prohibits the reconstruction of 2D cross sections. In this paper, we present a novel X-ray reflective mirror assembly for a more comprehensive screening of cargo containers. The proposed technique utilizes a micro-machined membrane deformable X-ray reflective mirror for efficient projection measurements. The deformable mirror compensates for the limited movement of the scan arrangement and yields high resolution 2D reconstruction
  • Keywords
    X-ray imaging; computerised tomography; micromechanical devices; MEMS; border security; cargo container screening; contraband goods; deformable X-ray reflective mirror; high energy X-ray imaging; micro-machined membrane; microelectromechanical system; nonintrusive imaging system; noninvasive detection; reduced false alarm; scan arrangement; screening modality; source detector arrangement; tomographic scanner; Containers; Image reconstruction; Micromechanical devices; Mirrors; Security; Tomography; Vehicles; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electro Information Technology, 2005 IEEE International Conference on
  • Conference_Location
    Lincoln, NE
  • Print_ISBN
    0-7803-9232-9
  • Type

    conf

  • DOI
    10.1109/EIT.2005.1626968
  • Filename
    1626968