Title :
A single-phase to three-phase quasiconverter. V. Design methodology
Author :
Fatic, Vuk M. ; Nquyen, C.Q.
Author_Institution :
Dept. of Electr. Eng. & Comput. Sci., Union Coll., Schenectady, NY, USA
Abstract :
For part IV see ibid., pp.362-7 (1988). Analytical relationships between the circuit parameters of the quasiconverter and the dynamical variables characterizing its electrical state, developed in Parts I-IV, are used for the inverse task: design of a quasiconverter for given specifications with maximum attainable efficiency. Two modes of operation are considered: with symmetric 3φ-voltages at no-load (T1C) and at a fixed load (T2C). The main result is that the T2C can attain the efficiency of at least 83%, while the T1C has the maximum efficiency of 62% for the same specifications
Keywords :
network synthesis; resonant power convertors; 62 percent; 83 percent; circuit parameters; design methodology; dynamical variables; efficiency; electrical state; fixed load; no-load; single-phase to three-phase quasiconverter; symmetric 3φ-voltages; Circuits; Constraint theory; Design methodology; Design optimization; Educational institutions; Impedance; Load management; Voltage;
Conference_Titel :
Circuits and Systems, 1995., Proceedings., Proceedings of the 38th Midwest Symposium on
Conference_Location :
Rio de Janeiro
Print_ISBN :
0-7803-2972-4
DOI :
10.1109/MWSCAS.1995.504412