• DocumentCode
    1856644
  • Title

    Ventricular tachycardia due to intramural figure eight reentry revealed by computerized three dimensional electrical activation mapping

  • Author

    Wu, Guanglie ; Littmann, Laszlo ; Svenson, Robert H. ; Nanney, Glenn ; Tatsis, George P. ; Tuntelder, Jan R. ; Chuang, Chi Hui ; Thompson, Michelle ; Dezern, Kethy R.

  • Author_Institution
    Laser & Appl. Technol. Lab., Carolinas Heart Inst., Charlotte, NC, USA
  • fYear
    1994
  • fDate
    3-6 Nov 1994
  • Firstpage
    11
  • Abstract
    A computerized three dimensional (3-D) ventricular electrical activation mapping system has been established in the authors´ laboratory. Two types of intramural figure eight reentry were found in induced monomorphic and polymorphic ventricular tachycardia (VT) in a canine model of subacute myocardial infarction
  • Keywords
    biological techniques; electrocardiography; laboratory techniques; medical signal processing; canine model; computerized three dimensional electrical activation mapping; intramural figure eight reentry; laboratory research technique; monomorphic ventricular tachycardia; polymorphic ventricular tachycardia; subacute myocardial infarction; Circuits; Computer displays; Electrocardiography; Electrodes; Heart rate variability; Laboratories; Laser modes; Lead; Myocardium; Needles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    0-7803-2050-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1994.412165
  • Filename
    412165