• DocumentCode
    1857783
  • Title

    Micro-particle filter made in SU-8 for biomedical applications

  • Author

    Noeth, N. ; Keller, S. ; Fetz, S. ; Geschke, O. ; Boisen, A.

  • Author_Institution
    DTU Nanotech, Tech. Univ. of Denmark, Lyngby, Denmark
  • fYear
    2009
  • fDate
    21-25 June 2009
  • Firstpage
    2034
  • Lastpage
    2037
  • Abstract
    We have integrated a micro-particle filter in a polymer cantilever to filter micro-particles from a fluid while simultaneously measuring the amount of filtered particles. In a 3,8 mum thick SU-8 cantilever a filter was integrated with pore sizes between 3 and 30 mum. The chip was inserted in a microfluidic system and water with differently sized polystyrene beads was pumped through the filter. Particles which are larger than the pore sizes, cannot pass the filter and will increase the flow resistance of the cantilever. With more and more captured particles the cantilever starts to deflect, which can be detected by an optical read-out system.
  • Keywords
    bioMEMS; biomedical equipment; biomedical materials; cantilevers; microfiltration; microfluidics; polymers; porosity; SU-8 cantilever; micro-particle filter; microfluidic system; optical read-out system; polymer cantilever; polystyrene beads; size 3 mum to 30 mum; Biomedical measurements; Biomedical optical imaging; Immune system; Microfluidics; Optical detectors; Optical filters; Particle measurements; Polymers; Pumps; Semiconductor device measurement; SU-8; cantilever; filter; microfluidic system;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid-State Sensors, Actuators and Microsystems Conference, 2009. TRANSDUCERS 2009. International
  • Conference_Location
    Denver, CO
  • Print_ISBN
    978-1-4244-4190-7
  • Electronic_ISBN
    978-1-4244-4193-8
  • Type

    conf

  • DOI
    10.1109/SENSOR.2009.5285663
  • Filename
    5285663