Abstract :
Two strontium lattice clocks, one in Japan and the other in Germany were directly compared by a two-way satellite frequency transfer technique that utilizes the carrier phase of the transmitted signal. The comparison has resulted in a fractional difference of 1.1(1.6)×10-15, directly confirming the frequency agreement on an intercontinental scale.
Keywords :
atomic clocks; frequency standards; strontium; transfer standards; TWSTFT; carrier phase two way satellite frequency transfer; frequency agreement; intercontinental scale; intercontinental separated lattice clock; signal transmission; Clocks; Lattices; Optical fibers; Satellites; Time-frequency analysis; TWSTFT; carrier phase; lattice clocks;
fLanguage :
English