• DocumentCode
    1859717
  • Title

    Calibration of a low voltage AC-DC transfer standard

  • Author

    Filipski, P.S. ; Rinfret, R.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • Volume
    1
  • fYear
    1998
  • fDate
    18-21 May 1998
  • Firstpage
    172
  • Abstract
    The paper describes a modification of a step-down calibration procedure for determining ac-dc transfer difference of an electronic low voltage transfer standard. The described procedure, utilizing an additional standard does not require corrections of the loading error. The paper shows that the input impedance of the standard changes from unit to unit and that each unit requires individual characterization, to be used to calibrate low voltage ac calibrators
  • Keywords
    calibration; measurement standards; power supply circuits; voltage measurement; 50 ohm; AC source calibration; AC-DC transfer difference; corrections; electronic low voltage transfer standard; input impedance; loading error; low voltage AC-DC transfer standard; low voltage ac calibrators; step down procedure; step-down calibration; Calibration; Circuit testing; Councils; Error correction; Frequency; Impedance; Low voltage; Measurement standards; Uncertainty; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1998. IMTC/98. Conference Proceedings. IEEE
  • Conference_Location
    St. Paul, MN
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-4797-8
  • Type

    conf

  • DOI
    10.1109/IMTC.1998.679750
  • Filename
    679750