• DocumentCode
    1860084
  • Title

    Low leak rate mems valves for micro-gas-analyzer flow control

  • Author

    Galambos, P. ; Lantz, J.W. ; James, C.D. ; McClain, J.L. ; Baker, M. ; Anderson, R. ; Simonson, R.J.

  • Author_Institution
    Sandia Nat. Labs., Albuquerque, NM, USA
  • fYear
    2009
  • fDate
    21-25 June 2009
  • Firstpage
    1658
  • Lastpage
    1661
  • Abstract
    We present MEMS polysilicon microvalves for flow control of a rapid analytical microsystem (Micro-Gas-Analyzer, MGA). All valve components (boss, seat, springs, electrodes, and stops) are surface micromachined in the SUMMiTtrade microfabrication process. The valves have been characterized at high flow rate when open (60 ml/min air), low leak rate when closed (<0.0025 ml/min Hydrogen, H2), and tunable closing pressures (1 to 35 psig). Active electrostatic valves have been shown to hold closed (voltage on) against a high pressure (>40 psig) for sample loading, open for gas chromatograph (GC) loading (voltage off), and reclose against low pressure 2-5 psig.
  • Keywords
    flow control; microfabrication; microfluidics; micromechanical devices; microvalves; MEMS valves; active electrostatic valves; flow control; gas chromatograph; micro-gas-analyzer; microfabrication process; polysilicon microvalves; surface micromachined; Electrodes; Electrostatics; Hydrogen; Insulation; Micromechanical devices; Microvalves; Pressure control; Springs; Valves; Voltage control; MEMS microvalve; Micro-Gas-Analyzer; electrostatic;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid-State Sensors, Actuators and Microsystems Conference, 2009. TRANSDUCERS 2009. International
  • Conference_Location
    Denver, CO
  • Print_ISBN
    978-1-4244-4190-7
  • Electronic_ISBN
    978-1-4244-4193-8
  • Type

    conf

  • DOI
    10.1109/SENSOR.2009.5285749
  • Filename
    5285749