Abstract
This paper describes the results of the lightning test for CPV system. The CPV system is provided with a tracking device. For 14kW system, the entire aperture area is 75 m2 and its height is approximately 10 m. This is relatively tall structure and subject to receive lightning damage. The IEC62305 standard describes the durability of CPV modules against lightning strike effect. Our test revealed that lightning current passed through the module´s aluminum chassis and flowed directly into the ground. Module IV measurement was performed, and no degradation or change was observer before and after the lightning test.
Keywords
IEC standards; lightning protection; solar cells; solar energy concentrators; testing; CPV modules; CPV system; IEC62305 standard; aluminum chassis; concentrator photovoltaic system; lightning current; lightning strike effect; lightning test; module IV measurement; power 14 kW; tracking device; Discharges; Electrodes; Fixtures; Lenses; Lightning protection; Power generation;