• DocumentCode
    1860789
  • Title

    Operation Of Single Phase Active Power Filter Under Weak AC Source

  • Author

    Kunjumuhammed, Linash P ; Mishra, Mahesh K

  • Author_Institution
    Indian Institute of Technology Madras, India. linashpk@ee.iitm.ac.in
  • fYear
    2006
  • fDate
    4-6 April 2006
  • Firstpage
    71
  • Lastpage
    75
  • Abstract
    The paper deals with operation of single-phase active power filter under weak ac source. In case of weak source, the voltage at point of common coupling (PCC) will be distorted because of the non-linear current drawn from the source. The paper presents a novel control algorithm to compute the reference filter current under distorted voltage. A synchronization circuit is presented, which is used to extract the zero crossing instance of the PCC voltage even under multiple zero crossings. Simulation and experimental results are presented to validate the proposed method.
  • Keywords
    Active power filter; harmonics; synchronization;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
  • Conference_Location
    The Contarf Castle, Dublin, Ireland
  • Print_ISBN
    0-86341-609-8
  • Type

    conf

  • Filename
    4123488