• DocumentCode
    1861893
  • Title

    Compare the Application of Two Different b-Value in Diffusion Weighted Imaged to Signal Differences on 3T MRI

  • Author

    Hsien-Wen Chiang ; Hsien-Jen Chiang ; Shih-Yu Chao ; Tzu-Chao Chuang ; Jie-Zhi Cheng

  • Author_Institution
    Dept. of Diagnostic Radiol. Chang Gung, Chang Gung Univ. Coll. of Med., Kaohsiung, Taiwan
  • fYear
    2013
  • fDate
    26-28 July 2013
  • Firstpage
    909
  • Lastpage
    912
  • Abstract
    Diffusion-weighted imaging is a specific MRI modality which is important for diagnosing brain infarction. In this study, we aim to find out that by using different b-values in DWI on 3T MRI for better diagnosis of acute or sub acute brain infarction. In 40 Patients with acute or sub acute brain infarction, we use the b-value 1000s/mm2 and 1500s/mm2 to process diffusion weighted images, and then these images were transferred to the imaging workstation for processing. We analyze the signal intensity and apparent diffusion coefficient (ADC) in the 1) infracted brain, 2) contra lateral normal brain, 3) background area of the infracted brain by circling the region of interest(ROI). It is shown that the higher b-value (1500s/mm2 compared to 1000s/mm2) yield lower signal intensity and ADC value in both the normal brain tissue and the infracted area, The signal to noise ratio (SNR) and contrast to noise ratio (CNR) also decrease as the b-value increases, Applying diffusion weighted imaging generated by the 3T MRI machine different b-values(1000s/mm2 and 1500s/mm2) to diagnose the brain infraction, we obtain better CNR and SNR by applying b-values 1000s/mm2 with statistically significant differences.
  • Keywords
    biodiffusion; biomedical MRI; brain; diseases; medical image processing; neurophysiology; 3T MRI machine; ADC value; CNR; DWI; ROI; SNR; acute brain infarction diagnosis; apparent diffusion coefficient; b-value; contralateral normal brain; contrast to noise ratio; diffusion weighted imaging; image processing; imaging workstation; infracted brain background area; normal brain tissue; region of interest; signal differences; signal intensity; signal to noise ratio; specific MRI modality; subacute brain infarction diagnosis; Attenuation; Blood flow; Brain; Magnetic fields; Magnetic resonance imaging; Signal to noise ratio; b-value; brain infarction; diffusion coefficient; diffusion weighted imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Image and Graphics (ICIG), 2013 Seventh International Conference on
  • Conference_Location
    Qingdao
  • Type

    conf

  • DOI
    10.1109/ICIG.2013.184
  • Filename
    6643801