DocumentCode
1862228
Title
IREN status: new electron linac driven intense resonance neutron source
Author
Krasnykh, A.
Author_Institution
JINR, Dubna, Russia
Volume
1
fYear
1995
fDate
1-5 May 1995
Firstpage
134
Abstract
Recently, JINR (Dubna) decided to erect a new accelerator driven intense resonance neutron spectrometer. Specifications in terms of output parameters are as follows. The integral neutron yield is approximately 1015 neutrons per second. The neutron pulse duration is approximately 400 ns. The repetition rate is 150 Hz. IREN source consists of a S-band linac, a multiplying target as a converter and a plutonium subcritical core. The present status of the S-band linac systems will be addressed
Keywords
electron accelerators; neutron sources; 150 Hz; 400 ns; IREN; S-band linac; electron linac; integral neutron yield; neutron pulse duration; repetition rate; resonance neutron source; Acceleration; Electron accelerators; Electron beams; Linear particle accelerator; Neutrons; Particle beams; Physics; Resonance; Spectroscopy; Structural beams;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.504589
Filename
504589
Link To Document