DocumentCode :
1862914
Title :
Plasma diagnosis in a miniature penning ion source by a mass-energy analyer
Author :
Fei Yan ; Dazhi Jin ; Lei Chen ; Xiang Wan
Author_Institution :
Inst. of Electron. Eng., Mianyang, China
fYear :
2015
fDate :
27-29 April 2015
Firstpage :
1
Lastpage :
2
Abstract :
Penning-type ion source performance for neutron generator applications is characterized partly by the atomic ion fraction. A miniature Penning ion source has been fabricated to investigate the atomic ion fraction of the deuterium plasma by a mass-energy analyer. The energy for the mass settings of 2 and 4, corresponding to D+ and D2+ ions respectively, show Guass distributions. The results show that the atomic ion fraction could vary from 2.26% to 5.63% by changing the pressure, the anode voltage and the discharge current. The results can provide useful information for the choosing of the discharge conditions.
Keywords :
Penning discharges; deuterium; ion sources; mass spectrometer accessories; plasma diagnostics; Guass distributions; Penning-type ion source performance; anode voltage; atomic ion fraction; deuterium plasma diagnosis; discharge current; mass-energy analyer; neutron generator applications; Deuterium; Ionization; Vacuum arcs; Valves; Penning ion source; atomic ion fraction; deuterium plasma;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Vacuum Electronics Conference (IVEC), 2015 IEEE International
Conference_Location :
Beijing
Print_ISBN :
978-1-4799-7109-1
Type :
conf
DOI :
10.1109/IVEC.2015.7223900
Filename :
7223900
Link To Document :
بازگشت