DocumentCode :
1869310
Title :
Short-range and high-resolution ultrasound imaging using an 8 MHz aluminum nitride PMUT array
Author :
Yipeng Lu ; Hao-Yen Tang ; Fung, Stephanie ; Boser, Bernhard E. ; Horsley, David A.
Author_Institution :
Berkeley Sensor & Actuator Center, Univ. of California, Davis, Davis, CA, USA
fYear :
2015
fDate :
18-22 Jan. 2015
Firstpage :
140
Lastpage :
143
Abstract :
Ultrasound imaging uses costly bulk piezoelectric transducers and high voltage (200V+) electronics. Low-cost and low-voltage ultrasound transducers would enable many new applications in healthcare, biometrics, and personal health-monitoring. Here, we demonstrated short-range (~mm) and high-resolution (<;100 μm) imaging based on piezoelectric micromachined ultrasonic transducers (PMUTs) and a 1.8 V interface ASIC. The PMUTs use piezoelectric Aluminum Nitride (AlN), which has the advantages of low-temperature (<;400 °C) deposition and compatibility with CMOS fabrication but has a relatively low piezoelectric constant (e31=-0.5 C/m2), making detection of ultrasound signals from tiny (50 μm) PMUTs a challenging task. To solve this problem, we developed an ASIC with a low-noise analog front-end pre-amplifier that is impedance matched to the PMUT. Furthermore, a novel beam-forming and scanning method was demonstrated to achieve a sub-100μm focus size and 70 μm scanning step. Pressure map measurement from phased PMUT array and pulse echo imaging results were demonstrated using 1-D and 2-D phantoms.
Keywords :
CMOS integrated circuits; III-V semiconductors; aluminium compounds; application specific integrated circuits; array signal processing; biomedical electronics; biomedical transducers; biomedical ultrasonics; image resolution; image sensors; impedance matching; medical image processing; micromachining; microsensors; phantoms; piezoelectric transducers; preamplifiers; pressure measurement; sensor arrays; signal detection; ultrasonic imaging; ultrasonic transducers; wide band gap semiconductors; 1D phantom; 2D phantom; ASIC interface; AlN; CMOS fabrication; aluminum nitride PMUT array; beamforming method; biometrics application; healthcare application; image resolution; impedance matching; low-noise analog front-end pre-amplifier; personal health-monitoring application; piezoelectric micromachined ultrasonic transducer; pressure map measurement; pulse echo imaging; scanning method; size 50 mum; ultrasound imaging; ultrasound signal detection; ultrasound transducer; voltage 1.8 V; Acoustic beams; Arrays; III-V semiconductor materials; Imaging; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Micro Electro Mechanical Systems (MEMS), 2015 28th IEEE International Conference on
Conference_Location :
Estoril
Type :
conf
DOI :
10.1109/MEMSYS.2015.7050905
Filename :
7050905
Link To Document :
بازگشت