• DocumentCode
    1871445
  • Title

    Improvement of accuracy in large sewer mean flow measurements using an array of Doppler transducers

  • Author

    Hughes, A.W. ; Longair, I.M.

  • Author_Institution
    Abertay Univ., Dundee, UK
  • fYear
    1996
  • fDate
    35173
  • Firstpage
    42552
  • Lastpage
    42556
  • Abstract
    The objective of the work was to produce a self-controlled, battery powered instrument that could produce velocity profile information across the section of a large sewer. The Doppler Transducer Velocity Array System was produced to meet this and testing has shown that the system functions as designed. Field testing of the system showed that the accuracy of the results recorded was to within 10.9% of an independent propeller meter. The transducer beams were forced to cross at specific positions and thus it was known exactly where in the flow the velocity readings originated
  • Keywords
    Doppler measurement; flow measurement; flowmeters; ultrasonic applications; ultrasonic transducer arrays; 3D representation; Doppler transducer velocity array system; US transducer; battery powered instrument; crossed transducer beams; field testing; improved accuracy; large sewer; mean flow measurements; multiple velocity measurements; self-controlled; storm data; weighted averaging;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Advances in Sensors for Fluid Flow Measurement, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19960575
  • Filename
    543308