Improvement of accuracy in large sewer mean flow measurements using an array of Doppler transducers
Author
Hughes, A.W. ; Longair, I.M.
Author_Institution
Abertay Univ., Dundee, UK
fYear
1996
fDate
35173
Firstpage
42552
Lastpage
42556
Abstract
The objective of the work was to produce a self-controlled, battery powered instrument that could produce velocity profile information across the section of a large sewer. The Doppler Transducer Velocity Array System was produced to meet this and testing has shown that the system functions as designed. Field testing of the system showed that the accuracy of the results recorded was to within 10.9% of an independent propeller meter. The transducer beams were forced to cross at specific positions and thus it was known exactly where in the flow the velocity readings originated
Keywords
Doppler measurement; flow measurement; flowmeters; ultrasonic applications; ultrasonic transducer arrays; 3D representation; Doppler transducer velocity array system; US transducer; battery powered instrument; crossed transducer beams; field testing; improved accuracy; large sewer; mean flow measurements; multiple velocity measurements; self-controlled; storm data; weighted averaging;