DocumentCode :
1871605
Title :
Calibration of time-of-flight range imaging cameras
Author :
Steiger, Olivier ; Felder, Judith ; Weiss, Stephan
Author_Institution :
ABB Switzerland Inc., Baden
fYear :
2008
fDate :
12-15 Oct. 2008
Firstpage :
1968
Lastpage :
1971
Abstract :
In this paper, a procedure for the systematic, generic and reproducible calibration of 3-D time-of-flight range imaging cameras is proposed. First, the effect of a number of internal and environmental influence factors is studied. Internal factors include the illumination radiation pattern, inner temperature and pixel integration period. Environmental factors are the ambient temperature, light, and target properties such as position, reflectance and color. Then, the influence of these factors is compensated. The procedure is illustrated with the SR-3000 camera, and validation results show that systematic improvements of the measurement accuracy have been obtained.
Keywords :
calibration; cameras; 3D time-of-flight range imaging cameras calibration; SR-3000 camera; ambient temperature; illumination radiation pattern; inner temperature; pixel integration period; Calibration; Cameras; Delay; Environmental factors; Lighting; Optical modulation; Phase detection; Phase modulation; Pulse measurements; Temperature; SR-3000; Time-of-flight; calibration; range imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image Processing, 2008. ICIP 2008. 15th IEEE International Conference on
Conference_Location :
San Diego, CA
ISSN :
1522-4880
Print_ISBN :
978-1-4244-1765-0
Electronic_ISBN :
1522-4880
Type :
conf
DOI :
10.1109/ICIP.2008.4712168
Filename :
4712168
Link To Document :
بازگشت